Intel Speed Select Technology Core Power (SST-CP) is an interface that allows users to define per core priority. This defines a mechanism to distribute power among cores when there is a power constrained scenario. This defines a class of service (CLOS) configuration. Three new IOCTLs are added: ISST_IF_CORE_POWER_STATE : Enable/Disable SST-CP ISST_IF_CLOS_PARAM : Configure CLOS parameters ISST_IF_CLOS_ASSOC : Associate CPUs to a CLOS To associate CPUs to CLOS, either Linux CPU numbering or PUNIT numbering scheme can be used, using parameter punit_cpu_map (1: for PUNIT numbering 0 for Linux CPU number). There is no change to IOCTL to get PUNIT CPU number for a CPU. Introduce get_instance() function, which is used by majority of IOCTLs processing to convert a socket and power domain to tpmi_per_power_domain_info * instance. This instance has all the MMIO offsets stored to read a particular field. Once an instance is identified, read or write from correct MMIO offset for a given field as defined in the specification. For details on SST CP operations using intel-speed-selet utility, refer to: Documentation/admin-guide/pm/intel-speed-select.rst under the kernel documentation
Showing the changes to include/uapi (1 of 2 files). Show all
Unified · Split
| @@ -163,6 +163,82 @@ struct isst_if_msr_cmds { · 162 unmodified lines | |||
| 163 | struct isst_if_msr_cmd msr_cmd[1]; | 163 | struct isst_if_msr_cmd msr_cmd[1]; |
| 164 | }; | 164 | }; |
| 165 | 165 | ||
| 166 | /** | ||
| 167 | * struct isst_core_power - Structure to get/set core_power feature | ||
| 168 | * @get_set: 0: Get, 1: Set | ||
| 169 | * @socket_id: Socket/package id | ||
| 170 | * @power_domain: Power Domain id | ||
| 171 | * @enable: Feature enable status | ||
| 172 | * @priority_type: Priority type for the feature (ordered/proportional) | ||
| 173 | * | ||
| 174 | * Structure to get/set core_power feature state using IOCTL | ||
| 175 | * ISST_IF_CORE_POWER_STATE. | ||
| 176 | */ | ||
| 177 | struct isst_core_power { | ||
| 178 | __u8 get_set; | ||
| 179 | __u8 socket_id; | ||
| 180 | __u8 power_domain_id; | ||
| 181 | __u8 enable; | ||
| 182 | __u8 supported; | ||
| 183 | __u8 priority_type; | ||
| 184 | }; | ||
| 185 | |||
| 186 | /** | ||
| 187 | * struct isst_clos_param - Structure to get/set clos praram | ||
| 188 | * @get_set: 0: Get, 1: Set | ||
| 189 | * @socket_id: Socket/package id | ||
| 190 | * @power_domain: Power Domain id | ||
| 191 | * clos: Clos ID for the parameters | ||
| 192 | * min_freq_mhz: Minimum frequency in MHz | ||
| 193 | * max_freq_mhz: Maximum frequency in MHz | ||
| 194 | * prop_prio: Proportional priority from 0-15 | ||
| 195 | * | ||
| 196 | * Structure to get/set per clos property using IOCTL | ||
| 197 | * ISST_IF_CLOS_PARAM. | ||
| 198 | */ | ||
| 199 | struct isst_clos_param { | ||
| 200 | __u8 get_set; | ||
| 201 | __u8 socket_id; | ||
| 202 | __u8 power_domain_id; | ||
| 203 | __u8 clos; | ||
| 204 | __u16 min_freq_mhz; | ||
| 205 | __u16 max_freq_mhz; | ||
| 206 | __u8 prop_prio; | ||
| 207 | }; | ||
| 208 | |||
| 209 | /** | ||
| 210 | * struct isst_if_clos_assoc - Structure to assign clos to a CPU | ||
| 211 | * @socket_id: Socket/package id | ||
| 212 | * @power_domain: Power Domain id | ||
| 213 | * @logical_cpu: CPU number | ||
| 214 | * @clos: Clos ID to assign to the logical CPU | ||
| 215 | * | ||
| 216 | * Structure to get/set core_power feature. | ||
| 217 | */ | ||
| 218 | struct isst_if_clos_assoc { | ||
| 219 | __u8 socket_id; | ||
| 220 | __u8 power_domain_id; | ||
| 221 | __u16 logical_cpu; | ||
| 222 | __u16 clos; | ||
| 223 | }; | ||
| 224 | |||
| 225 | /** | ||
| 226 | * struct isst_if_clos_assoc_cmds - Structure to assign clos to CPUs | ||
| 227 | * @cmd_count: Number of cmds (cpus) in this request | ||
| 228 | * @get_set: Request is for get or set | ||
| 229 | * @punit_cpu_map: Set to 1 if the CPU number is punit numbering not | ||
| 230 | * Linux CPU number | ||
| 231 | * | ||
| 232 | * Structure used to get/set associate CPUs to clos using IOCTL | ||
| 233 | * ISST_IF_CLOS_ASSOC. | ||
| 234 | */ | ||
| 235 | struct isst_if_clos_assoc_cmds { | ||
| 236 | __u16 cmd_count; | ||
| 237 | __u16 get_set; | ||
| 238 | __u16 punit_cpu_map; | ||
| 239 | struct isst_if_clos_assoc assoc_info[1]; | ||
| 240 | }; | ||
| 241 | |||
| 166 | /** | 242 | /** |
| 167 | * struct isst_tpmi_instance_count - Get number of TPMI instances per socket | 243 | * struct isst_tpmi_instance_count - Get number of TPMI instances per socket |
| 168 | * @socket_id: Socket/package id | 244 | * @socket_id: Socket/package id |
| @@ -186,5 +262,8 @@ struct isst_tpmi_instance_count { · 17 unmodified lines | |||
| 186 | #define ISST_IF_MSR_COMMAND _IOWR(ISST_IF_MAGIC, 4, struct isst_if_msr_cmds *) | 262 | #define ISST_IF_MSR_COMMAND _IOWR(ISST_IF_MAGIC, 4, struct isst_if_msr_cmds *) |
| 187 | 263 | ||
| 188 | #define ISST_IF_COUNT_TPMI_INSTANCES _IOR(ISST_IF_MAGIC, 5, struct isst_tpmi_instance_count *) | 264 | #define ISST_IF_COUNT_TPMI_INSTANCES _IOR(ISST_IF_MAGIC, 5, struct isst_tpmi_instance_count *) |
| 265 | #define ISST_IF_CORE_POWER_STATE _IOWR(ISST_IF_MAGIC, 6, struct isst_core_power *) | ||
| 266 | #define ISST_IF_CLOS_PARAM _IOWR(ISST_IF_MAGIC, 7, struct isst_clos_param *) | ||
| 267 | #define ISST_IF_CLOS_ASSOC _IOWR(ISST_IF_MAGIC, 8, struct isst_if_clos_assoc_cmds *) | ||
| 189 | 268 | ||
| 190 | #endif | 269 | #endif |