Intel Speed Select Technology Core Power (SST-CP) is an interface that allows users to define per core priority. This defines a mechanism to distribute power among cores when there is a power constrained scenario. This defines a class of service (CLOS) configuration. Three new IOCTLs are added: ISST_IF_CORE_POWER_STATE : Enable/Disable SST-CP ISST_IF_CLOS_PARAM : Configure CLOS parameters ISST_IF_CLOS_ASSOC : Associate CPUs to a CLOS To associate CPUs to CLOS, either Linux CPU numbering or PUNIT numbering scheme can be used, using parameter punit_cpu_map (1: for PUNIT numbering 0 for Linux CPU number). There is no change to IOCTL to get PUNIT CPU number for a CPU. Introduce get_instance() function, which is used by majority of IOCTLs processing to convert a socket and power domain to tpmi_per_power_domain_info * instance. This instance has all the MMIO offsets stored to read a particular field. Once an instance is identified, read or write from correct MMIO offset for a given field as defined in the specification. For details on SST CP operations using intel-speed-selet utility, refer to: Documentation/admin-guide/pm/intel-speed-select.rst under the kernel documentation
Showing the changes to include/uapi (1 of 2 files). Show all
Unified · Split
| @@ -163,6 +163,82 @@ struct isst_if_msr_cmds { · 162 unmodified lines | ||
| 163 | 163 | struct isst_if_msr_cmd msr_cmd[1]; |
| 164 | 164 | }; |
| 165 | 165 | |
| 166 | +/** | |
| 167 | + * struct isst_core_power - Structure to get/set core_power feature | |
| 168 | + * @get_set: 0: Get, 1: Set | |
| 169 | + * @socket_id: Socket/package id | |
| 170 | + * @power_domain: Power Domain id | |
| 171 | + * @enable: Feature enable status | |
| 172 | + * @priority_type: Priority type for the feature (ordered/proportional) | |
| 173 | + * | |
| 174 | + * Structure to get/set core_power feature state using IOCTL | |
| 175 | + * ISST_IF_CORE_POWER_STATE. | |
| 176 | + */ | |
| 177 | +struct isst_core_power { | |
| 178 | + __u8 get_set; | |
| 179 | + __u8 socket_id; | |
| 180 | + __u8 power_domain_id; | |
| 181 | + __u8 enable; | |
| 182 | + __u8 supported; | |
| 183 | + __u8 priority_type; | |
| 184 | +}; | |
| 185 | + | |
| 186 | +/** | |
| 187 | + * struct isst_clos_param - Structure to get/set clos praram | |
| 188 | + * @get_set: 0: Get, 1: Set | |
| 189 | + * @socket_id: Socket/package id | |
| 190 | + * @power_domain: Power Domain id | |
| 191 | + * clos: Clos ID for the parameters | |
| 192 | + * min_freq_mhz: Minimum frequency in MHz | |
| 193 | + * max_freq_mhz: Maximum frequency in MHz | |
| 194 | + * prop_prio: Proportional priority from 0-15 | |
| 195 | + * | |
| 196 | + * Structure to get/set per clos property using IOCTL | |
| 197 | + * ISST_IF_CLOS_PARAM. | |
| 198 | + */ | |
| 199 | +struct isst_clos_param { | |
| 200 | + __u8 get_set; | |
| 201 | + __u8 socket_id; | |
| 202 | + __u8 power_domain_id; | |
| 203 | + __u8 clos; | |
| 204 | + __u16 min_freq_mhz; | |
| 205 | + __u16 max_freq_mhz; | |
| 206 | + __u8 prop_prio; | |
| 207 | +}; | |
| 208 | + | |
| 209 | +/** | |
| 210 | + * struct isst_if_clos_assoc - Structure to assign clos to a CPU | |
| 211 | + * @socket_id: Socket/package id | |
| 212 | + * @power_domain: Power Domain id | |
| 213 | + * @logical_cpu: CPU number | |
| 214 | + * @clos: Clos ID to assign to the logical CPU | |
| 215 | + * | |
| 216 | + * Structure to get/set core_power feature. | |
| 217 | + */ | |
| 218 | +struct isst_if_clos_assoc { | |
| 219 | + __u8 socket_id; | |
| 220 | + __u8 power_domain_id; | |
| 221 | + __u16 logical_cpu; | |
| 222 | + __u16 clos; | |
| 223 | +}; | |
| 224 | + | |
| 225 | +/** | |
| 226 | + * struct isst_if_clos_assoc_cmds - Structure to assign clos to CPUs | |
| 227 | + * @cmd_count: Number of cmds (cpus) in this request | |
| 228 | + * @get_set: Request is for get or set | |
| 229 | + * @punit_cpu_map: Set to 1 if the CPU number is punit numbering not | |
| 230 | + * Linux CPU number | |
| 231 | + * | |
| 232 | + * Structure used to get/set associate CPUs to clos using IOCTL | |
| 233 | + * ISST_IF_CLOS_ASSOC. | |
| 234 | + */ | |
| 235 | +struct isst_if_clos_assoc_cmds { | |
| 236 | + __u16 cmd_count; | |
| 237 | + __u16 get_set; | |
| 238 | + __u16 punit_cpu_map; | |
| 239 | + struct isst_if_clos_assoc assoc_info[1]; | |
| 240 | +}; | |
| 241 | + | |
| 166 | 242 | /** |
| 167 | 243 | * struct isst_tpmi_instance_count - Get number of TPMI instances per socket |
| 168 | 244 | * @socket_id: Socket/package id |
| @@ -186,5 +262,8 @@ struct isst_tpmi_instance_count { · 17 unmodified lines | ||
| 186 | 262 | #define ISST_IF_MSR_COMMAND _IOWR(ISST_IF_MAGIC, 4, struct isst_if_msr_cmds *) |
| 187 | 263 | |
| 188 | 264 | #define ISST_IF_COUNT_TPMI_INSTANCES _IOR(ISST_IF_MAGIC, 5, struct isst_tpmi_instance_count *) |
| 265 | +#define ISST_IF_CORE_POWER_STATE _IOWR(ISST_IF_MAGIC, 6, struct isst_core_power *) | |
| 266 | +#define ISST_IF_CLOS_PARAM _IOWR(ISST_IF_MAGIC, 7, struct isst_clos_param *) | |
| 267 | +#define ISST_IF_CLOS_ASSOC _IOWR(ISST_IF_MAGIC, 8, struct isst_if_clos_assoc_cmds *) | |
| 189 | 268 | |
| 190 | 269 | #endif |