This patch adds support for the Analog Devices AD7787, AD7788, AD7789, AD7790 and AD7791 Sigma Delta Analog-to-Digital converters.
Showing the changes to include/linux/platform_data (1 of 4 files). Show all
Unified · Split
| @@ -0,0 +1,17 @@ | |||
| 1 | #ifndef __LINUX_PLATFORM_DATA_AD7791__ | ||
| 2 | #define __LINUX_PLATFORM_DATA_AD7791__ | ||
| 3 | |||
| 4 | /** | ||
| 5 | * struct ad7791_platform_data - AD7791 device platform data | ||
| 6 | * @buffered: If set to true configure the device for buffered input mode. | ||
| 7 | * @burnout_current: If set to true the 100mA burnout current is enabled. | ||
| 8 | * @unipolar: If set to true sample in unipolar mode, if set to false sample in | ||
| 9 | * bipolar mode. | ||
| 10 | */ | ||
| 11 | struct ad7791_platform_data { | ||
| 12 | bool buffered; | ||
| 13 | bool burnout_current; | ||
| 14 | bool unipolar; | ||
| 15 | }; | ||
| 16 | |||
| 17 | #endif | ||