| @@ -1,445 +0,0 @@ |
| 1 | // SPDX-License-Identifier: GPL-2.0-only | | |
| 2 | /* | | |
| 3 | * drivers/thermal/clock_cooling.c | | |
| 4 | * | | |
| 5 | * Copyright (C) 2014 Eduardo Valentin <edubezval@gmail.com> | | |
| 6 | * | | |
| 7 | * Copyright (C) 2013 Texas Instruments Inc. | | |
| 8 | * Contact: Eduardo Valentin <eduardo.valentin@ti.com> | | |
| 9 | * | | |
| 10 | * Highly based on cpufreq_cooling.c. | | |
| 11 | * Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com) | | |
| 12 | * Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org> | | |
| 13 | */ | | |
| 14 | #include <linux/clk.h> | | |
| 15 | #include <linux/clock_cooling.h> | | |
| 16 | #include <linux/cpufreq.h> | | |
| 17 | #include <linux/device.h> | | |
| 18 | #include <linux/err.h> | | |
| 19 | #include <linux/export.h> | | |
| 20 | #include <linux/idr.h> | | |
| 21 | #include <linux/mutex.h> | | |
| 22 | #include <linux/pm_opp.h> | | |
| 23 | #include <linux/slab.h> | | |
| 24 | #include <linux/thermal.h> | | |
| 25 | | | |
| 26 | /** | | |
| 27 | * struct clock_cooling_device - data for cooling device with clock | | |
| 28 | * @id: unique integer value corresponding to each clock_cooling_device | | |
| 29 | * registered. | | |
| 30 | * @dev: struct device pointer to the device being used to cool off using | | |
| 31 | * clock frequencies. | | |
| 32 | * @cdev: thermal_cooling_device pointer to keep track of the | | |
| 33 | * registered cooling device. | | |
| 34 | * @clk_rate_change_nb: reference to notifier block used to receive clock | | |
| 35 | * rate changes. | | |
| 36 | * @freq_table: frequency table used to keep track of available frequencies. | | |
| 37 | * @clock_state: integer value representing the current state of clock | | |
| 38 | * cooling devices. | | |
| 39 | * @clock_val: integer value representing the absolute value of the clipped | | |
| 40 | * frequency. | | |
| 41 | * @clk: struct clk reference used to enforce clock limits. | | |
| 42 | * @lock: mutex lock to protect this struct. | | |
| 43 | * | | |
| 44 | * This structure is required for keeping information of each | | |
| 45 | * clock_cooling_device registered. In order to prevent corruption of this a | | |
| 46 | * mutex @lock is used. | | |
| 47 | */ | | |
| 48 | struct clock_cooling_device { | | |
| 49 | int id; | | |
| 50 | struct device *dev; | | |
| 51 | struct thermal_cooling_device *cdev; | | |
| 52 | struct notifier_block clk_rate_change_nb; | | |
| 53 | struct cpufreq_frequency_table *freq_table; | | |
| 54 | unsigned long clock_state; | | |
| 55 | unsigned long clock_val; | | |
| 56 | struct clk *clk; | | |
| 57 | struct mutex lock; /* lock to protect the content of this struct */ | | |
| 58 | }; | | |
| 59 | #define to_clock_cooling_device(x) \ | | |
| 60 | container_of(x, struct clock_cooling_device, clk_rate_change_nb) | | |
| 61 | static DEFINE_IDA(clock_ida); | | |
| 62 | | | |
| 63 | /* Below code defines functions to be used for clock as cooling device */ | | |
| 64 | | | |
| 65 | enum clock_cooling_property { | | |
| 66 | GET_LEVEL, | | |
| 67 | GET_FREQ, | | |
| 68 | GET_MAXL, | | |
| 69 | }; | | |
| 70 | | | |
| 71 | /** | | |
| 72 | * clock_cooling_get_property - fetch a property of interest for a give cpu. | | |
| 73 | * @ccdev: clock cooling device reference | | |
| 74 | * @input: query parameter | | |
| 75 | * @output: query return | | |
| 76 | * @property: type of query (frequency, level, max level) | | |
| 77 | * | | |
| 78 | * This is the common function to | | |
| 79 | * 1. get maximum clock cooling states | | |
| 80 | * 2. translate frequency to cooling state | | |
| 81 | * 3. translate cooling state to frequency | | |
| 82 | * Note that the code may be not in good shape | | |
| 83 | * but it is written in this way in order to: | | |
| 84 | * a) reduce duplicate code as most of the code can be shared. | | |
| 85 | * b) make sure the logic is consistent when translating between | | |
| 86 | * cooling states and frequencies. | | |
| 87 | * | | |
| 88 | * Return: 0 on success, -EINVAL when invalid parameters are passed. | | |
| 89 | */ | | |
| 90 | static int clock_cooling_get_property(struct clock_cooling_device *ccdev, | | |
| 91 | unsigned long input, | | |
| 92 | unsigned long *output, | | |
| 93 | enum clock_cooling_property property) | | |
| 94 | { | | |
| 95 | int i; | | |
| 96 | unsigned long max_level = 0, level = 0; | | |
| 97 | unsigned int freq = CPUFREQ_ENTRY_INVALID; | | |
| 98 | int descend = -1; | | |
| 99 | struct cpufreq_frequency_table *pos, *table = ccdev->freq_table; | | |
| 100 | | | |
| 101 | if (!output) | | |
| 102 | return -EINVAL; | | |
| 103 | | | |
| 104 | if (!table) | | |
| 105 | return -EINVAL; | | |
| 106 | | | |
| 107 | cpufreq_for_each_valid_entry(pos, table) { | | |
| 108 | /* ignore duplicate entry */ | | |
| 109 | if (freq == pos->frequency) | | |
| 110 | continue; | | |
| 111 | | | |
| 112 | /* get the frequency order */ | | |
| 113 | if (freq != CPUFREQ_ENTRY_INVALID && descend == -1) | | |
| 114 | descend = freq > pos->frequency; | | |
| 115 | | | |
| 116 | freq = pos->frequency; | | |
| 117 | max_level++; | | |
| 118 | } | | |
| 119 | | | |
| 120 | /* No valid cpu frequency entry */ | | |
| 121 | if (max_level == 0) | | |
| 122 | return -EINVAL; | | |
| 123 | | | |
| 124 | /* max_level is an index, not a counter */ | | |
| 125 | max_level--; | | |
| 126 | | | |
| 127 | /* get max level */ | | |
| 128 | if (property == GET_MAXL) { | | |
| 129 | *output = max_level; | | |
| 130 | return 0; | | |
| 131 | } | | |
| 132 | | | |
| 133 | if (property == GET_FREQ) | | |
| 134 | level = descend ? input : (max_level - input); | | |
| 135 | | | |
| 136 | i = 0; | | |
| 137 | cpufreq_for_each_valid_entry(pos, table) { | | |
| 138 | /* ignore duplicate entry */ | | |
| 139 | if (freq == pos->frequency) | | |
| 140 | continue; | | |
| 141 | | | |
| 142 | /* now we have a valid frequency entry */ | | |
| 143 | freq = pos->frequency; | | |
| 144 | | | |
| 145 | if (property == GET_LEVEL && (unsigned int)input == freq) { | | |
| 146 | /* get level by frequency */ | | |
| 147 | *output = descend ? i : (max_level - i); | | |
| 148 | return 0; | | |
| 149 | } | | |
| 150 | if (property == GET_FREQ && level == i) { | | |
| 151 | /* get frequency by level */ | | |
| 152 | *output = freq; | | |
| 153 | return 0; | | |
| 154 | } | | |
| 155 | i++; | | |
| 156 | } | | |
| 157 | | | |
| 158 | return -EINVAL; | | |
| 159 | } | | |
| 160 | | | |
| 161 | /** | | |
| 162 | * clock_cooling_get_level - return the cooling level of given clock cooling. | | |
| 163 | * @cdev: reference of a thermal cooling device of used as clock cooling device | | |
| 164 | * @freq: the frequency of interest | | |
| 165 | * | | |
| 166 | * This function will match the cooling level corresponding to the | | |
| 167 | * requested @freq and return it. | | |
| 168 | * | | |
| 169 | * Return: The matched cooling level on success or THERMAL_CSTATE_INVALID | | |
| 170 | * otherwise. | | |
| 171 | */ | | |
| 172 | unsigned long clock_cooling_get_level(struct thermal_cooling_device *cdev, | | |
| 173 | unsigned long freq) | | |
| 174 | { | | |
| 175 | struct clock_cooling_device *ccdev = cdev->devdata; | | |
| 176 | unsigned long val; | | |
| 177 | | | |
| 178 | if (clock_cooling_get_property(ccdev, (unsigned long)freq, &val, | | |
| 179 | GET_LEVEL)) | | |
| 180 | return THERMAL_CSTATE_INVALID; | | |
| 181 | | | |
| 182 | return val; | | |
| 183 | } | | |
| 184 | EXPORT_SYMBOL_GPL(clock_cooling_get_level); | | |
| 185 | | | |
| 186 | /** | | |
| 187 | * clock_cooling_get_frequency - get the absolute value of frequency from level. | | |
| 188 | * @ccdev: clock cooling device reference | | |
| 189 | * @level: cooling level | | |
| 190 | * | | |
| 191 | * This function matches cooling level with frequency. Based on a cooling level | | |
| 192 | * of frequency, equals cooling state of cpu cooling device, it will return | | |
| 193 | * the corresponding frequency. | | |
| 194 | * e.g level=0 --> 1st MAX FREQ, level=1 ---> 2nd MAX FREQ, .... etc | | |
| 195 | * | | |
| 196 | * Return: 0 on error, the corresponding frequency otherwise. | | |
| 197 | */ | | |
| 198 | static unsigned long | | |
| 199 | clock_cooling_get_frequency(struct clock_cooling_device *ccdev, | | |
| 200 | unsigned long level) | | |
| 201 | { | | |
| 202 | int ret = 0; | | |
| 203 | unsigned long freq; | | |
| 204 | | | |
| 205 | ret = clock_cooling_get_property(ccdev, level, &freq, GET_FREQ); | | |
| 206 | if (ret) | | |
| 207 | return 0; | | |
| 208 | | | |
| 209 | return freq; | | |
| 210 | } | | |
| 211 | | | |
| 212 | /** | | |
| 213 | * clock_cooling_apply - function to apply frequency clipping. | | |
| 214 | * @ccdev: clock_cooling_device pointer containing frequency clipping data. | | |
| 215 | * @cooling_state: value of the cooling state. | | |
| 216 | * | | |
| 217 | * Function used to make sure the clock layer is aware of current thermal | | |
| 218 | * limits. The limits are applied by updating the clock rate in case it is | | |
| 219 | * higher than the corresponding frequency based on the requested cooling_state. | | |
| 220 | * | | |
| 221 | * Return: 0 on success, an error code otherwise (-EINVAL in case wrong | | |
| 222 | * cooling state). | | |
| 223 | */ | | |
| 224 | static int clock_cooling_apply(struct clock_cooling_device *ccdev, | | |
| 225 | unsigned long cooling_state) | | |
| 226 | { | | |
| 227 | unsigned long clip_freq, cur_freq; | | |
| 228 | int ret = 0; | | |
| 229 | | | |
| 230 | /* Here we write the clipping */ | | |
| 231 | /* Check if the old cooling action is same as new cooling action */ | | |
| 232 | if (ccdev->clock_state == cooling_state) | | |
| 233 | return 0; | | |
| 234 | | | |
| 235 | clip_freq = clock_cooling_get_frequency(ccdev, cooling_state); | | |
| 236 | if (!clip_freq) | | |
| 237 | return -EINVAL; | | |
| 238 | | | |
| 239 | cur_freq = clk_get_rate(ccdev->clk); | | |
| 240 | | | |
| 241 | mutex_lock(&ccdev->lock); | | |
| 242 | ccdev->clock_state = cooling_state; | | |
| 243 | ccdev->clock_val = clip_freq; | | |
| 244 | /* enforce clock level */ | | |
| 245 | if (cur_freq > clip_freq) | | |
| 246 | ret = clk_set_rate(ccdev->clk, clip_freq); | | |
| 247 | mutex_unlock(&ccdev->lock); | | |
| 248 | | | |
| 249 | return ret; | | |
| 250 | } | | |
| 251 | | | |
| 252 | /** | | |
| 253 | * clock_cooling_clock_notifier - notifier callback on clock rate changes. | | |
| 254 | * @nb: struct notifier_block * with callback info. | | |
| 255 | * @event: value showing clock event for which this function invoked. | | |
| 256 | * @data: callback-specific data | | |
| 257 | * | | |
| 258 | * Callback to hijack the notification on clock transition. | | |
| 259 | * Every time there is a clock change, we intercept all pre change events | | |
| 260 | * and block the transition in case the new rate infringes thermal limits. | | |
| 261 | * | | |
| 262 | * Return: NOTIFY_DONE (success) or NOTIFY_BAD (new_rate > thermal limit). | | |
| 263 | */ | | |
| 264 | static int clock_cooling_clock_notifier(struct notifier_block *nb, | | |
| 265 | unsigned long event, void *data) | | |
| 266 | { | | |
| 267 | struct clk_notifier_data *ndata = data; | | |
| 268 | struct clock_cooling_device *ccdev = to_clock_cooling_device(nb); | | |
| 269 | | | |
| 270 | switch (event) { | | |
| 271 | case PRE_RATE_CHANGE: | | |
| 272 | /* | | |
| 273 | * checks on current state | | |
| 274 | * TODO: current method is not best we can find as it | | |
| 275 | * allows possibly voltage transitions, in case DVFS | | |
| 276 | * layer is also hijacking clock pre notifications. | | |
| 277 | */ | | |
| 278 | if (ndata->new_rate > ccdev->clock_val) | | |
| 279 | return NOTIFY_BAD; | | |
| 280 | /* fall through */ | | |
| 281 | case POST_RATE_CHANGE: | | |
| 282 | case ABORT_RATE_CHANGE: | | |
| 283 | default: | | |
| 284 | return NOTIFY_DONE; | | |
| 285 | } | | |
| 286 | } | | |
| 287 | | | |
| 288 | /* clock cooling device thermal callback functions are defined below */ | | |
| 289 | | | |
| 290 | /** | | |
| 291 | * clock_cooling_get_max_state - callback function to get the max cooling state. | | |
| 292 | * @cdev: thermal cooling device pointer. | | |
| 293 | * @state: fill this variable with the max cooling state. | | |
| 294 | * | | |
| 295 | * Callback for the thermal cooling device to return the clock | | |
| 296 | * max cooling state. | | |
| 297 | * | | |
| 298 | * Return: 0 on success, an error code otherwise. | | |
| 299 | */ | | |
| 300 | static int clock_cooling_get_max_state(struct thermal_cooling_device *cdev, | | |
| 301 | unsigned long *state) | | |
| 302 | { | | |
| 303 | struct clock_cooling_device *ccdev = cdev->devdata; | | |
| 304 | unsigned long count = 0; | | |
| 305 | int ret; | | |
| 306 | | | |
| 307 | ret = clock_cooling_get_property(ccdev, 0, &count, GET_MAXL); | | |
| 308 | if (!ret) | | |
| 309 | *state = count; | | |
| 310 | | | |
| 311 | return ret; | | |
| 312 | } | | |
| 313 | | | |
| 314 | /** | | |
| 315 | * clock_cooling_get_cur_state - function to get the current cooling state. | | |
| 316 | * @cdev: thermal cooling device pointer. | | |
| 317 | * @state: fill this variable with the current cooling state. | | |
| 318 | * | | |
| 319 | * Callback for the thermal cooling device to return the clock | | |
| 320 | * current cooling state. | | |
| 321 | * | | |
| 322 | * Return: 0 (success) | | |
| 323 | */ | | |
| 324 | static int clock_cooling_get_cur_state(struct thermal_cooling_device *cdev, | | |
| 325 | unsigned long *state) | | |
| 326 | { | | |
| 327 | struct clock_cooling_device *ccdev = cdev->devdata; | | |
| 328 | | | |
| 329 | *state = ccdev->clock_state; | | |
| 330 | | | |
| 331 | return 0; | | |
| 332 | } | | |
| 333 | | | |
| 334 | /** | | |
| 335 | * clock_cooling_set_cur_state - function to set the current cooling state. | | |
| 336 | * @cdev: thermal cooling device pointer. | | |
| 337 | * @state: set this variable to the current cooling state. | | |
| 338 | * | | |
| 339 | * Callback for the thermal cooling device to change the clock cooling | | |
| 340 | * current cooling state. | | |
| 341 | * | | |
| 342 | * Return: 0 on success, an error code otherwise. | | |
| 343 | */ | | |
| 344 | static int clock_cooling_set_cur_state(struct thermal_cooling_device *cdev, | | |
| 345 | unsigned long state) | | |
| 346 | { | | |
| 347 | struct clock_cooling_device *clock_device = cdev->devdata; | | |
| 348 | | | |
| 349 | return clock_cooling_apply(clock_device, state); | | |
| 350 | } | | |
| 351 | | | |
| 352 | /* Bind clock callbacks to thermal cooling device ops */ | | |
| 353 | static struct thermal_cooling_device_ops const clock_cooling_ops = { | | |
| 354 | .get_max_state = clock_cooling_get_max_state, | | |
| 355 | .get_cur_state = clock_cooling_get_cur_state, | | |
| 356 | .set_cur_state = clock_cooling_set_cur_state, | | |
| 357 | }; | | |
| 358 | | | |
| 359 | /** | | |
| 360 | * clock_cooling_register - function to create clock cooling device. | | |
| 361 | * @dev: struct device pointer to the device used as clock cooling device. | | |
| 362 | * @clock_name: string containing the clock used as cooling mechanism. | | |
| 363 | * | | |
| 364 | * This interface function registers the clock cooling device with the name | | |
| 365 | * "thermal-clock-%x". The cooling device is based on clock frequencies. | | |
| 366 | * The struct device is assumed to be capable of DVFS transitions. | | |
| 367 | * The OPP layer is used to fetch and fill the available frequencies for | | |
| 368 | * the referred device. The ordered frequency table is used to control | | |
| 369 | * the clock cooling device cooling states and to limit clock transitions | | |
| 370 | * based on the cooling state requested by the thermal framework. | | |
| 371 | * | | |
| 372 | * Return: a valid struct thermal_cooling_device pointer on success, | | |
| 373 | * on failure, it returns a corresponding ERR_PTR(). | | |
| 374 | */ | | |
| 375 | struct thermal_cooling_device * | | |
| 376 | clock_cooling_register(struct device *dev, const char *clock_name) | | |
| 377 | { | | |
| 378 | struct thermal_cooling_device *cdev; | | |
| 379 | struct clock_cooling_device *ccdev = NULL; | | |
| 380 | char dev_name[THERMAL_NAME_LENGTH]; | | |
| 381 | int ret = 0; | | |
| 382 | | | |
| 383 | ccdev = devm_kzalloc(dev, sizeof(*ccdev), GFP_KERNEL); | | |
| 384 | if (!ccdev) | | |
| 385 | return ERR_PTR(-ENOMEM); | | |
| 386 | | | |
| 387 | mutex_init(&ccdev->lock); | | |
| 388 | ccdev->dev = dev; | | |
| 389 | ccdev->clk = devm_clk_get(dev, clock_name); | | |
| 390 | if (IS_ERR(ccdev->clk)) | | |
| 391 | return ERR_CAST(ccdev->clk); | | |
| 392 | | | |
| 393 | ret = ida_simple_get(&clock_ida, 0, 0, GFP_KERNEL); | | |
| 394 | if (ret < 0) | | |
| 395 | return ERR_PTR(ret); | | |
| 396 | ccdev->id = ret; | | |
| 397 | | | |
| 398 | snprintf(dev_name, sizeof(dev_name), "thermal-clock-%d", ccdev->id); | | |
| 399 | | | |
| 400 | cdev = thermal_cooling_device_register(dev_name, ccdev, | | |
| 401 | &clock_cooling_ops); | | |
| 402 | if (IS_ERR(cdev)) { | | |
| 403 | ida_simple_remove(&clock_ida, ccdev->id); | | |
| 404 | return ERR_PTR(-EINVAL); | | |
| 405 | } | | |
| 406 | ccdev->cdev = cdev; | | |
| 407 | ccdev->clk_rate_change_nb.notifier_call = clock_cooling_clock_notifier; | | |
| 408 | | | |
| 409 | /* Assuming someone has already filled the opp table for this device */ | | |
| 410 | ret = dev_pm_opp_init_cpufreq_table(dev, &ccdev->freq_table); | | |
| 411 | if (ret) { | | |
| 412 | ida_simple_remove(&clock_ida, ccdev->id); | | |
| 413 | return ERR_PTR(ret); | | |
| 414 | } | | |
| 415 | ccdev->clock_state = 0; | | |
| 416 | ccdev->clock_val = clock_cooling_get_frequency(ccdev, 0); | | |
| 417 | | | |
| 418 | clk_notifier_register(ccdev->clk, &ccdev->clk_rate_change_nb); | | |
| 419 | | | |
| 420 | return cdev; | | |
| 421 | } | | |
| 422 | EXPORT_SYMBOL_GPL(clock_cooling_register); | | |
| 423 | | | |
| 424 | /** | | |
| 425 | * clock_cooling_unregister - function to remove clock cooling device. | | |
| 426 | * @cdev: thermal cooling device pointer. | | |
| 427 | * | | |
| 428 | * This interface function unregisters the "thermal-clock-%x" cooling device. | | |
| 429 | */ | | |
| 430 | void clock_cooling_unregister(struct thermal_cooling_device *cdev) | | |
| 431 | { | | |
| 432 | struct clock_cooling_device *ccdev; | | |
| 433 | | | |
| 434 | if (!cdev) | | |
| 435 | return; | | |
| 436 | | | |
| 437 | ccdev = cdev->devdata; | | |
| 438 | | | |
| 439 | clk_notifier_unregister(ccdev->clk, &ccdev->clk_rate_change_nb); | | |
| 440 | dev_pm_opp_free_cpufreq_table(ccdev->dev, &ccdev->freq_table); | | |
| 441 | | | |
| 442 | thermal_cooling_device_unregister(ccdev->cdev); | | |
| 443 | ida_simple_remove(&clock_ida, ccdev->id); | | |
| 444 | } | | |