| @@ -0,0 +1,185 @@ |
| | 1 | // SPDX-License-Identifier: GPL-2.0 |
| | 2 | /* |
| | 3 | * NVM Express device driver verbose errors |
| | 4 | * Copyright (c) 2022, Oracle and/or its affiliates |
| | 5 | */ |
| | 6 | |
| | 7 | #include <linux/blkdev.h> |
| | 8 | #include "nvme.h" |
| | 9 | |
| | 10 | #ifdef CONFIG_NVME_VERBOSE_ERRORS |
| | 11 | static const char * const nvme_ops[] = { |
| | 12 | [nvme_cmd_flush] = "Flush", |
| | 13 | [nvme_cmd_write] = "Write", |
| | 14 | [nvme_cmd_read] = "Read", |
| | 15 | [nvme_cmd_write_uncor] = "Write Uncorrectable", |
| | 16 | [nvme_cmd_compare] = "Compare", |
| | 17 | [nvme_cmd_write_zeroes] = "Write Zeros", |
| | 18 | [nvme_cmd_dsm] = "Dataset Management", |
| | 19 | [nvme_cmd_verify] = "Verify", |
| | 20 | [nvme_cmd_resv_register] = "Reservation Register", |
| | 21 | [nvme_cmd_resv_report] = "Reservation Report", |
| | 22 | [nvme_cmd_resv_acquire] = "Reservation Acquire", |
| | 23 | [nvme_cmd_resv_release] = "Reservation Release", |
| | 24 | [nvme_cmd_zone_mgmt_send] = "Zone Management Send", |
| | 25 | [nvme_cmd_zone_mgmt_recv] = "Zone Management Receive", |
| | 26 | [nvme_cmd_zone_append] = "Zone Management Append", |
| | 27 | }; |
| | 28 | |
| | 29 | static const char * const nvme_admin_ops[] = { |
| | 30 | [nvme_admin_delete_sq] = "Delete SQ", |
| | 31 | [nvme_admin_create_sq] = "Create SQ", |
| | 32 | [nvme_admin_get_log_page] = "Get Log Page", |
| | 33 | [nvme_admin_delete_cq] = "Delete CQ", |
| | 34 | [nvme_admin_create_cq] = "Create CQ", |
| | 35 | [nvme_admin_identify] = "Identify", |
| | 36 | [nvme_admin_abort_cmd] = "Abort Command", |
| | 37 | [nvme_admin_set_features] = "Set Features", |
| | 38 | [nvme_admin_get_features] = "Get Features", |
| | 39 | [nvme_admin_async_event] = "Async Event", |
| | 40 | [nvme_admin_ns_mgmt] = "Namespace Management", |
| | 41 | [nvme_admin_activate_fw] = "Activate Firmware", |
| | 42 | [nvme_admin_download_fw] = "Download Firmware", |
| | 43 | [nvme_admin_dev_self_test] = "Device Self Test", |
| | 44 | [nvme_admin_ns_attach] = "Namespace Attach", |
| | 45 | [nvme_admin_keep_alive] = "Keep Alive", |
| | 46 | [nvme_admin_directive_send] = "Directive Send", |
| | 47 | [nvme_admin_directive_recv] = "Directive Receive", |
| | 48 | [nvme_admin_virtual_mgmt] = "Virtual Management", |
| | 49 | [nvme_admin_nvme_mi_send] = "NVMe Send MI", |
| | 50 | [nvme_admin_nvme_mi_recv] = "NVMe Receive MI", |
| | 51 | [nvme_admin_dbbuf] = "Doorbell Buffer Config", |
| | 52 | [nvme_admin_format_nvm] = "Format NVM", |
| | 53 | [nvme_admin_security_send] = "Security Send", |
| | 54 | [nvme_admin_security_recv] = "Security Receive", |
| | 55 | [nvme_admin_sanitize_nvm] = "Sanitize NVM", |
| | 56 | [nvme_admin_get_lba_status] = "Get LBA Status", |
| | 57 | }; |
| | 58 | |
| | 59 | static const char * const nvme_statuses[] = { |
| | 60 | [NVME_SC_SUCCESS] = "Success", |
| | 61 | [NVME_SC_INVALID_OPCODE] = "Invalid Command Opcode", |
| | 62 | [NVME_SC_INVALID_FIELD] = "Invalid Field in Command", |
| | 63 | [NVME_SC_CMDID_CONFLICT] = "Command ID Conflict", |
| | 64 | [NVME_SC_DATA_XFER_ERROR] = "Data Transfer Error", |
| | 65 | [NVME_SC_POWER_LOSS] = "Commands Aborted due to Power Loss Notification", |
| | 66 | [NVME_SC_INTERNAL] = "Internal Error", |
| | 67 | [NVME_SC_ABORT_REQ] = "Command Abort Requested", |
| | 68 | [NVME_SC_ABORT_QUEUE] = "Command Aborted due to SQ Deletion", |
| | 69 | [NVME_SC_FUSED_FAIL] = "Command Aborted due to Failed Fused Command", |
| | 70 | [NVME_SC_FUSED_MISSING] = "Command Aborted due to Missing Fused Command", |
| | 71 | [NVME_SC_INVALID_NS] = "Invalid Namespace or Format", |
| | 72 | [NVME_SC_CMD_SEQ_ERROR] = "Command Sequence Error", |
| | 73 | [NVME_SC_SGL_INVALID_LAST] = "Invalid SGL Segment Descriptor", |
| | 74 | [NVME_SC_SGL_INVALID_COUNT] = "Invalid Number of SGL Descriptors", |
| | 75 | [NVME_SC_SGL_INVALID_DATA] = "Data SGL Length Invalid", |
| | 76 | [NVME_SC_SGL_INVALID_METADATA] = "Metadata SGL Length Invalid", |
| | 77 | [NVME_SC_SGL_INVALID_TYPE] = "SGL Descriptor Type Invalid", |
| | 78 | [NVME_SC_CMB_INVALID_USE] = "Invalid Use of Controller Memory Buffer", |
| | 79 | [NVME_SC_PRP_INVALID_OFFSET] = "PRP Offset Invalid", |
| | 80 | [NVME_SC_ATOMIC_WU_EXCEEDED] = "Atomic Write Unit Exceeded", |
| | 81 | [NVME_SC_OP_DENIED] = "Operation Denied", |
| | 82 | [NVME_SC_SGL_INVALID_OFFSET] = "SGL Offset Invalid", |
| | 83 | [NVME_SC_RESERVED] = "Reserved", |
| | 84 | [NVME_SC_HOST_ID_INCONSIST] = "Host Identifier Inconsistent Format", |
| | 85 | [NVME_SC_KA_TIMEOUT_EXPIRED] = "Keep Alive Timeout Expired", |
| | 86 | [NVME_SC_KA_TIMEOUT_INVALID] = "Keep Alive Timeout Invalid", |
| | 87 | [NVME_SC_ABORTED_PREEMPT_ABORT] = "Command Aborted due to Preempt and Abort", |
| | 88 | [NVME_SC_SANITIZE_FAILED] = "Sanitize Failed", |
| | 89 | [NVME_SC_SANITIZE_IN_PROGRESS] = "Sanitize In Progress", |
| | 90 | [NVME_SC_SGL_INVALID_GRANULARITY] = "SGL Data Block Granularity Invalid", |
| | 91 | [NVME_SC_CMD_NOT_SUP_CMB_QUEUE] = "Command Not Supported for Queue in CMB", |
| | 92 | [NVME_SC_NS_WRITE_PROTECTED] = "Namespace is Write Protected", |
| | 93 | [NVME_SC_CMD_INTERRUPTED] = "Command Interrupted", |
| | 94 | [NVME_SC_TRANSIENT_TR_ERR] = "Transient Transport Error", |
| | 95 | [NVME_SC_INVALID_IO_CMD_SET] = "Invalid IO Command Set", |
| | 96 | [NVME_SC_LBA_RANGE] = "LBA Out of Range", |
| | 97 | [NVME_SC_CAP_EXCEEDED] = "Capacity Exceeded", |
| | 98 | [NVME_SC_NS_NOT_READY] = "Namespace Not Ready", |
| | 99 | [NVME_SC_RESERVATION_CONFLICT] = "Reservation Conflict", |
| | 100 | [NVME_SC_FORMAT_IN_PROGRESS] = "Format In Progress", |
| | 101 | [NVME_SC_CQ_INVALID] = "Completion Queue Invalid", |
| | 102 | [NVME_SC_QID_INVALID] = "Invalid Queue Identifier", |
| | 103 | [NVME_SC_QUEUE_SIZE] = "Invalid Queue Size", |
| | 104 | [NVME_SC_ABORT_LIMIT] = "Abort Command Limit Exceeded", |
| | 105 | [NVME_SC_ABORT_MISSING] = "Reserved", /* XXX */ |
| | 106 | [NVME_SC_ASYNC_LIMIT] = "Asynchronous Event Request Limit Exceeded", |
| | 107 | [NVME_SC_FIRMWARE_SLOT] = "Invalid Firmware Slot", |
| | 108 | [NVME_SC_FIRMWARE_IMAGE] = "Invalid Firmware Image", |
| | 109 | [NVME_SC_INVALID_VECTOR] = "Invalid Interrupt Vector", |
| | 110 | [NVME_SC_INVALID_LOG_PAGE] = "Invalid Log Page", |
| | 111 | [NVME_SC_INVALID_FORMAT] = "Invalid Format", |
| | 112 | [NVME_SC_FW_NEEDS_CONV_RESET] = "Firmware Activation Requires Conventional Reset", |
| | 113 | [NVME_SC_INVALID_QUEUE] = "Invalid Queue Deletion", |
| | 114 | [NVME_SC_FEATURE_NOT_SAVEABLE] = "Feature Identifier Not Saveable", |
| | 115 | [NVME_SC_FEATURE_NOT_CHANGEABLE] = "Feature Not Changeable", |
| | 116 | [NVME_SC_FEATURE_NOT_PER_NS] = "Feature Not Namespace Specific", |
| | 117 | [NVME_SC_FW_NEEDS_SUBSYS_RESET] = "Firmware Activation Requires NVM Subsystem Reset", |
| | 118 | [NVME_SC_FW_NEEDS_RESET] = "Firmware Activation Requires Reset", |
| | 119 | [NVME_SC_FW_NEEDS_MAX_TIME] = "Firmware Activation Requires Maximum Time Violation", |
| | 120 | [NVME_SC_FW_ACTIVATE_PROHIBITED] = "Firmware Activation Prohibited", |
| | 121 | [NVME_SC_OVERLAPPING_RANGE] = "Overlapping Range", |
| | 122 | [NVME_SC_NS_INSUFFICIENT_CAP] = "Namespace Insufficient Capacity", |
| | 123 | [NVME_SC_NS_ID_UNAVAILABLE] = "Namespace Identifier Unavailable", |
| | 124 | [NVME_SC_NS_ALREADY_ATTACHED] = "Namespace Already Attached", |
| | 125 | [NVME_SC_NS_IS_PRIVATE] = "Namespace Is Private", |
| | 126 | [NVME_SC_NS_NOT_ATTACHED] = "Namespace Not Attached", |
| | 127 | [NVME_SC_THIN_PROV_NOT_SUPP] = "Thin Provisioning Not Supported", |
| | 128 | [NVME_SC_CTRL_LIST_INVALID] = "Controller List Invalid", |
| | 129 | [NVME_SC_SELT_TEST_IN_PROGRESS] = "Device Self-test In Progress", |
| | 130 | [NVME_SC_BP_WRITE_PROHIBITED] = "Boot Partition Write Prohibited", |
| | 131 | [NVME_SC_CTRL_ID_INVALID] = "Invalid Controller Identifier", |
| | 132 | [NVME_SC_SEC_CTRL_STATE_INVALID] = "Invalid Secondary Controller State", |
| | 133 | [NVME_SC_CTRL_RES_NUM_INVALID] = "Invalid Number of Controller Resources", |
| | 134 | [NVME_SC_RES_ID_INVALID] = "Invalid Resource Identifier", |
| | 135 | [NVME_SC_PMR_SAN_PROHIBITED] = "Sanitize Prohibited", |
| | 136 | [NVME_SC_ANA_GROUP_ID_INVALID] = "ANA Group Identifier Invalid", |
| | 137 | [NVME_SC_ANA_ATTACH_FAILED] = "ANA Attach Failed", |
| | 138 | [NVME_SC_BAD_ATTRIBUTES] = "Conflicting Attributes", |
| | 139 | [NVME_SC_INVALID_PI] = "Invalid Protection Information", |
| | 140 | [NVME_SC_READ_ONLY] = "Attempted Write to Read Only Range", |
| | 141 | [NVME_SC_ONCS_NOT_SUPPORTED] = "ONCS Not Supported", |
| | 142 | [NVME_SC_ZONE_BOUNDARY_ERROR] = "Zoned Boundary Error", |
| | 143 | [NVME_SC_ZONE_FULL] = "Zone Is Full", |
| | 144 | [NVME_SC_ZONE_READ_ONLY] = "Zone Is Read Only", |
| | 145 | [NVME_SC_ZONE_OFFLINE] = "Zone Is Offline", |
| | 146 | [NVME_SC_ZONE_INVALID_WRITE] = "Zone Invalid Write", |
| | 147 | [NVME_SC_ZONE_TOO_MANY_ACTIVE] = "Too Many Active Zones", |
| | 148 | [NVME_SC_ZONE_TOO_MANY_OPEN] = "Too Many Open Zones", |
| | 149 | [NVME_SC_ZONE_INVALID_TRANSITION] = "Invalid Zone State Transition", |
| | 150 | [NVME_SC_WRITE_FAULT] = "Write Fault", |
| | 151 | [NVME_SC_READ_ERROR] = "Unrecovered Read Error", |
| | 152 | [NVME_SC_GUARD_CHECK] = "End-to-end Guard Check Error", |
| | 153 | [NVME_SC_APPTAG_CHECK] = "End-to-end Application Tag Check Error", |
| | 154 | [NVME_SC_REFTAG_CHECK] = "End-to-end Reference Tag Check Error", |
| | 155 | [NVME_SC_COMPARE_FAILED] = "Compare Failure", |
| | 156 | [NVME_SC_ACCESS_DENIED] = "Access Denied", |
| | 157 | [NVME_SC_UNWRITTEN_BLOCK] = "Deallocated or Unwritten Logical Block", |
| | 158 | [NVME_SC_ANA_PERSISTENT_LOSS] = "Asymmetric Access Persistent Loss", |
| | 159 | [NVME_SC_ANA_INACCESSIBLE] = "Asymmetric Access Inaccessible", |
| | 160 | [NVME_SC_ANA_TRANSITION] = "Asymmetric Access Transition", |
| | 161 | [NVME_SC_HOST_PATH_ERROR] = "Host Pathing Error", |
| | 162 | }; |
| | 163 | |
| | 164 | const unsigned char *nvme_get_error_status_str(u16 status) |
| | 165 | { |
| | 166 | status &= 0x7ff; |
| | 167 | if (status < ARRAY_SIZE(nvme_statuses) && nvme_statuses[status]) |
| | 168 | return nvme_statuses[status & 0x7ff]; |
| | 169 | return "Unknown"; |
| | 170 | } |
| | 171 | |
| | 172 | const unsigned char *nvme_get_opcode_str(u8 opcode) |
| | 173 | { |
| | 174 | if (opcode < ARRAY_SIZE(nvme_ops) && nvme_ops[opcode]) |
| | 175 | return nvme_ops[opcode]; |
| | 176 | return "Unknown"; |
| | 177 | } |
| | 178 | |
| | 179 | const unsigned char *nvme_get_admin_opcode_str(u8 opcode) |
| | 180 | { |
| | 181 | if (opcode < ARRAY_SIZE(nvme_admin_ops) && nvme_admin_ops[opcode]) |
| | 182 | return nvme_admin_ops[opcode]; |
| | 183 | return "Unknown"; |
| | 184 | } |
| | 185 | #endif /* CONFIG_NVME_VERBOSE_ERRORS */ |