History

doc/bitstream_filters.texi: Document types used by filter_units

Andreas Rheinhardt committed 2 years ago

Commit cc95fd41 parent 2c82ec91 file · +7 −0Browse files

Unified · Split

doc/bitstream_filters.texi+7−0
@@ -199,6 +199,13 @@ Identical to @option{pass_types}, except the units in the given set · 198 unmodified lines
199199 removed and all others passed through.
200200 @end table
201201
202+The types used by pass_types and remove_types correspond to NAL unit types
203+(nal_unit_type) in H.264, HEVC and H.266 (see Table 7-1 in the H.264
204+and HEVC specifications or Table 5 in the H.266 specification), to
205+marker values for JPEG (without 0xFF prefix) and to start codes without
206+start code prefix (i.e. the byte following the 0x000001) for MPEG-2.
207+For VP8 and VP9, every unit has type zero.
208+
202209 Extradata is unchanged by this transformation, but note that if the stream
203210 contains inline parameter sets then the output may be unusable if they are
204211 removed.