History

GSF.TimeSeries: Rolled-up schema changes to support remote ADO database setups and applied consistency changes to scripts to support roll-down to all time-series implementations.

ritchiecarroll committed 13 years ago

Commit 2dc3ce91 parent 80affe88 files · +889 −340Browse files

Showing the changes to Source/Libraries/GSF.TimeSeries/Data/Oracle/SampleDataSet.sql (1 of 8 files). Show all

Unified · Split

Source/Libraries/GSF.TimeSeries/Data/Oracle/SampleDataSet.sql+58−48
@@ -1,64 +1,74 @@
11 INSERT INTO Node(Name, CompanyID, Description, Settings, MenuType, MenuData, Master, LoadOrder, Enabled)
2− VALUES('Default', NULL, 'Default node', 'RemoteStatusServerConnectionString={server=localhost:8500;integratedSecurity=true};dataPublisherPort=6165',
3− 'File', 'Menu.xml', 1, 0, 1);
2+ VALUES('Default', NULL, 'Default node', 'RemoteStatusServerConnectionString={server=localhost:8500;integratedSecurity=true};dataPublisherPort=6165', 'File', 'Menu.xml', 1, 0, 1);
3+
44 UPDATE Node SET ID='e7a5235d-cb6f-4864-a96e-a8686f36e599' WHERE Name='Default';
5−INSERT INTO Historian(NodeID, Acronym, Name, AssemblyName, TypeName, ConnectionString, IsLocal, Description, LoadOrder, Enabled) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 'PPA', 'Primary Phasor Archive', 'HistorianAdapters.dll', 'HistorianAdapters.LocalOutputAdapter', '', 1, 'Local development archive', 0, 1);
6−INSERT INTO Device(NodeID, Acronym, Name, IsConcentrator, CompanyID, HistorianID, AccessID, VendorDeviceID, ProtocolID, Longitude, Latitude, InterconnectionID, ConnectionString, MeasuredLines, LoadOrder, Enabled) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 'SHELBY', 'Shelby', 0, 30, 1, 2, 2, 3, -89.8038, 35.3871, 1, 'transportProtocol=File; file=Sample1344.PmuCapture; useHighResolutionInputTimer=True', 3, 0, 1);
5+
6+INSERT INTO Historian(NodeID, Acronym, Name, AssemblyName, TypeName, ConnectionString, IsLocal, Description, LoadOrder, Enabled) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 'PPA', 'Primary Phasor Archive', 'HistorianAdapters.dll', 'HistorianAdapters.LocalOutputAdapter', '', 1, 'Primary Phasor Archive', 0, 1);
7+INSERT INTO Device(NodeID, Acronym, Name, IsConcentrator, CompanyID, HistorianID, AccessID, VendorDeviceID, ProtocolID, Longitude, Latitude, InterconnectionID, ConnectionString, MeasuredLines, LoadOrder, Enabled) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 'TESTDEVICE', 'Test Device', 0, 30, 1, 2, 2, 3, -89.8038, 35.3871, 1, 'transportProtocol=File; file=Sample1344.PmuCapture; useHighResolutionInputTimer=True', 3, 0, 1);
8+
79 INSERT INTO Phasor(DeviceID, Label, Type, Phase, SourceIndex) VALUES(1, '500 kV Bus 1', 'V', '+', 1);
810 INSERT INTO Phasor(DeviceID, Label, Type, Phase, SourceIndex) VALUES(1, '500 kV Bus 2', 'V', '+', 2);
911 INSERT INTO Phasor(DeviceID, Label, Type, Phase, SourceIndex) VALUES(1, 'Cordova', 'I', '+', 3);
1012 INSERT INTO Phasor(DeviceID, Label, Type, Phase, SourceIndex) VALUES(1, 'Dell', 'I', '+', 4);
1113 INSERT INTO Phasor(DeviceID, Label, Type, Phase, SourceIndex) VALUES(1, 'Lagoon Creek', 'I', '+', 5);
12−INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_SHELBY:ABBS', 8, NULL, 'SHELBY-SF', 'Shelby ABB-521 Status Flags', 1);
13−UPDATE Measurement SET SignalID='7aaf0a8f-3a4f-4c43-ab43-ed9d1e64a255' WHERE PointTag='TVA_SHELBY:ABBS';
14−INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_SHELBY:ABBF', 5, NULL, 'SHELBY-FQ', 'Shelby ABB-521 Frequency', 1);
15−UPDATE Measurement SET SignalID='93673c68-d59d-4926-b7e9-e7678f9f66b4' WHERE PointTag='TVA_SHELBY:ABBF';
16−INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_SHELBY:ABBD1', 9, NULL, 'SHELBY-DV1', 'Shelby ABB-521 Digital Value 1', 1);
17−UPDATE Measurement SET SignalID='65ac9cf6-ae33-4ece-91b6-bb79343855d5' WHERE PointTag='TVA_SHELBY:ABBD1';
18−INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_SHELBY:ABBDF', 6, NULL, 'SHELBY-DF', 'Shelby ABB-521 Frequency Delta (dF/dt)', 1);
19−UPDATE Measurement SET SignalID='3647f729-d0ed-4f79-85ad-dae2149cd432' WHERE PointTag='TVA_SHELBY:ABBDF';
20−INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_SHELBY-BUS1:ABBV', 3, 1, 'SHELBY-PM1', 'Shelby ABB-521 500 kV Bus 1 Positive Sequence Voltage Magnitude', 1);
21−UPDATE Measurement SET SignalID='069c5e29-f78a-46f6-9dff-c92cb4f69371' WHERE PointTag='TVA_SHELBY-BUS1:ABBV';
22−INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_SHELBY-BUS1:ABBVH', 4, 1, 'SHELBY-PA1', 'Shelby ABB-521 500 kV Bus 1 Positive Sequence Voltage Phase Angle', 1);
23−UPDATE Measurement SET SignalID='25355a7b-2a9d-4ef2-99ba-4dd791461379' WHERE PointTag='TVA_SHELBY-BUS1:ABBVH';
24−INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_SHELBY-BUS2:ABBV', 3, 2, 'SHELBY-PM2', 'Shelby ABB-521 500 kV Bus 2 Positive Sequence Voltage Magnitude', 1);
25−UPDATE Measurement SET SignalID='ee130f0f-8c94-414f-b081-9551ffb73753' WHERE PointTag='TVA_SHELBY-BUS2:ABBV';
26−INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_SHELBY-BUS2:ABBVH', 4, 2, 'SHELBY-PA2', 'Shelby ABB-521 500 kV Bus 2 Positive Sequence Voltage Phase Angle', 1);
27−UPDATE Measurement SET SignalID='96cb33be-f7e4-4dfe-a20a-50976aa507fd' WHERE PointTag='TVA_SHELBY-BUS2:ABBVH';
28−INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_SHELBY-CORD:ABBI', 1, 3, 'SHELBY-PM3', 'Shelby ABB-521 Cordova Positive Sequence Current Magnitude', 1);
29−UPDATE Measurement SET SignalID='34172112-0565-4ad7-b314-f0876d978751' WHERE PointTag='TVA_SHELBY-CORD:ABBI';
30−INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_SHELBY-CORD:ABBIH', 2, 3, 'SHELBY-PA3', 'Shelby ABB-521 Cordova Positive Sequence Current Phase Angle', 1);
31−UPDATE Measurement SET SignalID='70e72607-dbbc-458b-9c66-5fd32b447a03' WHERE PointTag='TVA_SHELBY-CORD:ABBIH';
32−INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_SHELBY-DELL:ABBI', 1, 4, 'SHELBY-PM4', 'Shelby ABB-521 Dell Positive Sequence Current Magnitude', 1);
33−UPDATE Measurement SET SignalID='28bbb1fc-3434-48d3-87a8-bf5024c089d5' WHERE PointTag='TVA_SHELBY-DELL:ABBI';
34−INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_SHELBY-DELL:ABBIH', 2, 4, 'SHELBY-PA4', 'Shelby ABB-521 Dell Positive Sequence Current Phase Angle', 1);
35−UPDATE Measurement SET SignalID='c635e906-8bfb-486d-901e-46c8e07afdc3' WHERE PointTag='TVA_SHELBY-DELL:ABBIH';
36−INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_SHELBY-LAGO:ABBI', 1, 5, 'SHELBY-PM5', 'Shelby ABB-521 Lagoon Creek Positive Sequence Current Magnitude', 1);
37−UPDATE Measurement SET SignalID='ed6def67-54c4-4e74-af95-c95fa6915fbc' WHERE PointTag='TVA_SHELBY-LAGO:ABBI';
38−INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_SHELBY-LAGO:ABBIH', 2, 5, 'SHELBY-PA5', 'Shelby ABB-521 Lagoon Creek Positive Sequence Current Phase Angle', 1);
39−UPDATE Measurement SET SignalID='bcd7aa41-32f1-4d3c-96d5-9e1da2c9469e' WHERE PointTag='TVA_SHELBY-LAGO:ABBIH';
14+
15+INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE:ABBS', 8, NULL, 'TESTDEVICE-SF', 'Test Device ABB-521 Status Flags', 1);
16+INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE:ABBF', 5, NULL, 'TESTDEVICE-FQ', 'Test Device ABB-521 Frequency', 1);
17+INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE:ABBD1', 9, NULL, 'TESTDEVICE-DV1', 'Test Device ABB-521 Digital Value 1', 1);
18+INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE:ABBDF', 6, NULL, 'TESTDEVICE-DF', 'Test Device ABB-521 Frequency Delta (dF/dt)', 1);
19+INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-BUS1:ABBV', 3, 1, 'TESTDEVICE-PM1', 'Test Device ABB-521 500 kV Bus 1 Positive Sequence Voltage Magnitude', 1);
20+INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-BUS1:ABBVH', 4, 1, 'TESTDEVICE-PA1', 'Test Device ABB-521 500 kV Bus 1 Positive Sequence Voltage Phase Angle', 1);
21+INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-BUS2:ABBV', 3, 2, 'TESTDEVICE-PM2', 'Test Device ABB-521 500 kV Bus 2 Positive Sequence Voltage Magnitude', 1);
22+INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-BUS2:ABBVH', 4, 2, 'TESTDEVICE-PA2', 'Test Device ABB-521 500 kV Bus 2 Positive Sequence Voltage Phase Angle', 1);
23+INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-CORD:ABBI', 1, 3, 'TESTDEVICE-PM3', 'Test Device ABB-521 Cordova Positive Sequence Current Magnitude', 1);
24+INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-CORD:ABBIH', 2, 3, 'TESTDEVICE-PA3', 'Test Device ABB-521 Cordova Positive Sequence Current Phase Angle', 1);
25+INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-DELL:ABBI', 1, 4, 'TESTDEVICE-PM4', 'Test Device ABB-521 Dell Positive Sequence Current Magnitude', 1);
26+INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-DELL:ABBIH', 2, 4, 'TESTDEVICE-PA4', 'Test Device ABB-521 Dell Positive Sequence Current Phase Angle', 1);
27+INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-LAGO:ABBI', 1, 5, 'TESTDEVICE-PM5', 'Test Device ABB-521 Lagoon Creek Positive Sequence Current Magnitude', 1);
28+INSERT INTO Measurement(HistorianID, DeviceID, PointTag, SignalTypeID, PhasorSourceIndex, SignalReference, Description, Enabled) VALUES(1, 1, 'TVA_TESTDEVICE-LAGO:ABBIH', 2, 5, 'TESTDEVICE-PA5', 'Test Device ABB-521 Lagoon Creek Positive Sequence Current Phase Angle', 1);
29+
30+--UPDATE Measurement SET SignalID='7aaf0a8f-3a4f-4c43-ab43-ed9d1e64a255' WHERE PointTag='TVA_TESTDEVICE:ABBS';
31+--UPDATE Measurement SET SignalID='93673c68-d59d-4926-b7e9-e7678f9f66b4' WHERE PointTag='TVA_TESTDEVICE:ABBF';
32+--UPDATE Measurement SET SignalID='65ac9cf6-ae33-4ece-91b6-bb79343855d5' WHERE PointTag='TVA_TESTDEVICE:ABBD1';
33+--UPDATE Measurement SET SignalID='3647f729-d0ed-4f79-85ad-dae2149cd432' WHERE PointTag='TVA_TESTDEVICE:ABBDF';
34+--UPDATE Measurement SET SignalID='069c5e29-f78a-46f6-9dff-c92cb4f69371' WHERE PointTag='TVA_TESTDEVICE-BUS1:ABBV';
35+--UPDATE Measurement SET SignalID='25355a7b-2a9d-4ef2-99ba-4dd791461379' WHERE PointTag='TVA_TESTDEVICE-BUS1:ABBVH';
36+--UPDATE Measurement SET SignalID='ee130f0f-8c94-414f-b081-9551ffb73753' WHERE PointTag='TVA_TESTDEVICE-BUS2:ABBV';
37+--UPDATE Measurement SET SignalID='96cb33be-f7e4-4dfe-a20a-50976aa507fd' WHERE PointTag='TVA_TESTDEVICE-BUS2:ABBVH';
38+--UPDATE Measurement SET SignalID='34172112-0565-4ad7-b314-f0876d978751' WHERE PointTag='TVA_TESTDEVICE-CORD:ABBI';
39+--UPDATE Measurement SET SignalID='70e72607-dbbc-458b-9c66-5fd32b447a03' WHERE PointTag='TVA_TESTDEVICE-CORD:ABBIH';
40+--UPDATE Measurement SET SignalID='28bbb1fc-3434-48d3-87a8-bf5024c089d5' WHERE PointTag='TVA_TESTDEVICE-DELL:ABBI';
41+--UPDATE Measurement SET SignalID='c635e906-8bfb-486d-901e-46c8e07afdc3' WHERE PointTag='TVA_TESTDEVICE-DELL:ABBIH';
42+--UPDATE Measurement SET SignalID='ed6def67-54c4-4e74-af95-c95fa6915fbc' WHERE PointTag='TVA_TESTDEVICE-LAGO:ABBI';
43+--UPDATE Measurement SET SignalID='bcd7aa41-32f1-4d3c-96d5-9e1da2c9469e' WHERE PointTag='TVA_TESTDEVICE-LAGO:ABBIH';
44+
4045 INSERT INTO OutputStream(NodeID, Acronym, Name, Type, ConnectionString, DataChannel, CommandChannel, IDCode, AutoPublishConfigFrame, AutoStartDataChannel, NominalFrequency, FramesPerSecond, LagTime, LeadTime, UseLocalClockAsRealTime, AllowSortsByArrival, LoadOrder, Enabled) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 'TESTSTREAM', 'Test Stream', 0, '', 'Port=-1;Clients=localhost:8800', 'Port=8900', 235, 0, 1, 60, 30, 0.001, 2, 0, 1, 0, 1);
41−INSERT INTO OutputStreamDevice(NodeID, AdapterID, IDCode, Acronym, BpaAcronym, Name, LoadOrder, Enabled) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 2, 'SHELBY', 'SHEL', 'Shelby', 0, 1);
42−INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 1, 'SHELBY-SF');
43−INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 2, 'SHELBY-FQ');
44−INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 3, 'SHELBY-DV1');
45−INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 4, 'SHELBY-DF');
46−INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 5, 'SHELBY-PM1');
47−INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 6, 'SHELBY-PA1');
48−INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 7, 'SHELBY-PM2');
49−INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 8, 'SHELBY-PA2');
50−INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 9, 'SHELBY-PM3');
51−INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 10, 'SHELBY-PA3');
52−INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 11, 'SHELBY-PM4');
53−INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 12, 'SHELBY-PA4');
54−INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 13, 'SHELBY-PM5');
55−INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 14, 'SHELBY-PA5');
46+
47+INSERT INTO OutputStreamDevice(NodeID, AdapterID, IDCode, Acronym, BpaAcronym, Name, LoadOrder, Enabled) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 2, 'TESTDEVICE', 'TEST', 'Test Device', 0, 1);
48+
49+INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 1, 'TESTDEVICE-SF');
50+INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 2, 'TESTDEVICE-FQ');
51+INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 3, 'TESTDEVICE-DV1');
52+INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 4, 'TESTDEVICE-DF');
53+INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 5, 'TESTDEVICE-PM1');
54+INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 6, 'TESTDEVICE-PA1');
55+INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 7, 'TESTDEVICE-PM2');
56+INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 8, 'TESTDEVICE-PA2');
57+INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 9, 'TESTDEVICE-PM3');
58+INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 10, 'TESTDEVICE-PA3');
59+INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 11, 'TESTDEVICE-PM4');
60+INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 12, 'TESTDEVICE-PA4');
61+INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 13, 'TESTDEVICE-PM5');
62+INSERT INTO OutputStreamMeasurement(NodeID, AdapterID, HistorianID, PointID, SignalReference) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 1, 14, 'TESTDEVICE-PA5');
63+
5664 INSERT INTO OutputStreamDevicePhasor(NodeID, OutputStreamDeviceID, Label, Type, Phase, LoadOrder) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, '500 kV Bus 1', 'V', '+', 0);
5765 INSERT INTO OutputStreamDevicePhasor(NodeID, OutputStreamDeviceID, Label, Type, Phase, LoadOrder) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, '500 kV Bus 2', 'V', '+', 1);
5866 INSERT INTO OutputStreamDevicePhasor(NodeID, OutputStreamDeviceID, Label, Type, Phase, LoadOrder) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 'Cordova', 'I', '+', 2);
5967 INSERT INTO OutputStreamDevicePhasor(NodeID, OutputStreamDeviceID, Label, Type, Phase, LoadOrder) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 'Dell', 'I', '+', 3);
6068 INSERT INTO OutputStreamDevicePhasor(NodeID, OutputStreamDeviceID, Label, Type, Phase, LoadOrder) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 'Lagoon Creek', 'I', '+', 4);
69+
6170 INSERT INTO OutputStreamDeviceDigital(NodeID, OutputStreamDeviceID, Label, LoadOrder) VALUES('e7a5235d-cb6f-4864-a96e-a8686f36e599', 1, 'Digital1', 0);
71+
6272 INSERT INTO ApplicationRole (Name, Description, NodeID) VALUES ('Administrator', 'Administrator Role', 'e7a5235d-cb6f-4864-a96e-a8686f36e599');
6373 INSERT INTO ApplicationRole (Name, Description, NodeID) VALUES ('Editor', 'Editor', 'e7a5235d-cb6f-4864-a96e-a8686f36e599');
64−INSERT INTO ApplicationRole (Name, Description, NodeID) VALUES ('Viewer', 'Viewer Role', 'e7a5235d-cb6f-4864-a96e-a8686f36e599');
74+INSERT INTO ApplicationRole (Name, Description, NodeID) VALUES ('Viewer', 'Viewer Role', 'e7a5235d-cb6f-4864-a96e-a8686f36e599');

Keyboard shortcuts

General

Show keyboard shortcuts
?
Focus the current search
/

Issues and pull requests

Open filters
f

Issues, pull requests and Inbox

Select next item
j↓
Select previous item
k↑
Open selected item
Enter
Dismiss filters or clear selection
Esc

Repository code

Go to file
t