Filter Expressions
Filter expressions can be used to filter inputs and outputs for streams, subscribers and adapters.
This syntax is similar to a SQL WHERE clause, but does not implement the full SQL language. See DataTable.Select() for more information.
Filtering Syntax
FILTER <TableName> [TOP n] WHERE <Expression> [ORDER BY <SortField>]
Available Options and Clauses
Examples
An example input filter to only pass measurements with the company of GPA and type of Frequency(FREQ).
inputMeasurementKeys = {
FILTER ActiveMeasurements WHERE Company='GPA' AND SignalType='FREQ' ORDER BY ID
};
An example input filter to only pass first 20 Statistics(STAT) measurments.
inputMeasurementKeys = {
FILTER TOP 20 ActiveMeasurements WHERE SignalType = 'STAT'
};
An example output filter to only send Current Angle and Voltage Angle for the Positive Sequence(+) measurments.
outputMeasurements = {
FILTER ActiveMeasurements WHERE SignalType IN ('IPHA','VPHA') AND Phase='+' ORDER BY PhasorID
};
See more examples of allowed DataTable.Select() syntax.
Available Table Definitions
Available table defintions are defined in the ConfigurationEntity table of the host Time-Series Library application configuration database.
For selection of input and output measurements for adapters, ActiveMeasurements is the most common source. Other commonly defined tables are listed here for reference as well.
ActiveMeasurements
| ColumnName |
DataType |
| SourceNodeID |
Guid |
| ID |
string |
| SignalID |
Guid |
| PointTag |
string |
| AlternateTag |
string |
| SignalReference |
string |
| Internal |
int |
| Subscribed |
int |
| Device |
string |
| DeviceID |
int |
| FramesPerSecond |
int |
| Protocol |
string |
| ProtocolType |
string |
| SignalType |
string |
| EngineeringUnits |
string |
| PhasorID |
int |
| PhasorType |
string |
| Phase |
string |
| Adder |
double |
| Multiplier |
double |
| Company |
string |
| Longitude |
Decimal |
| Latitude |
Decimal |
| Description |
string |
| UpdatedOn |
DateTime |
ActionAdapters
| ColumnName |
DataType |
| ID |
int |
| AdapterName |
string |
| AssemblyName |
string |
| TypeName |
string |
| Connectionstring |
string |
Alarms
| ColumnName |
DataType |
| ID |
int |
| TagName |
string |
| SignalID |
Guid |
| AssociatedMeasurementID |
Guid |
| Description |
string |
| Severity |
int |
| Operation |
int |
| SetPoint |
double |
| Tolerance |
double |
| Delay |
double |
| Hysteresis |
double |
| LoadOrder |
int |
| Enabled |
bool |
| CreatedOn |
DateTime |
| CreatedBy |
string |
| UpdatedOn |
DateTime |
| UpdatedBy |
string |
Alarm Severity Values
| Value |
Acronym |
Description |
| 0 |
None |
Alarm is of no importance |
| 50 |
Info |
Alarm is informative, but not dangerous |
| 150 |
Low |
Alarm is not very important |
| 300 |
MedLow |
Alarm is somewhat important |
| 500 |
Med |
Alarm is moderately important |
| 700 |
MedHigh |
Alarm is important |
| 850 |
High |
Alarm is very important |
| 900 |
Range |
Alarm for a value that is unreasonable |
| 950 |
Critical |
Alarm signifies a dangerous situation |
| 980 |
FlatLine |
Alarm value is latched |
| 1000 |
Error |
Alarm reports bad data |
ConfigurationDataSet
| ColumnName |
DataType |
| Version |
string |
ConfigurationEntity
| ColumnName |
DataType |
| SourceName |
string |
| RuntimeName |
string |
| Description |
string |
| LoadOrder |
int |
| Enabled |
bool |
InputAdapters
| ColumnName |
DataType |
| ID |
int |
| AdapterName |
string |
| AssemblyName |
string |
| TypeName |
string |
| Connectionstring |
string |
InputStreamDevices
| ColumnName |
DataType |
| ParentID |
int |
| ID |
int |
| Acronym |
string |
| Name |
string |
| AccessID |
int |
MeasurementGroupMeasurements
| ColumnName |
DataType |
| MeasurementGroupID |
int |
| SignalID |
Guid |
| CreatedOn |
DateTime |
| CreatedBy |
string |
| UpdatedOn |
DateTime |
| UpdatedBy |
string |
MeasurementGroups
| ColumnName |
DataType |
| ID |
int |
| Name |
string |
| Description |
string |
| FilterExpression |
string |
| CreatedOn |
DateTime |
| CreatedBy |
string |
| UpdatedOn |
DateTime |
| UpdatedBy |
string |
NodeInfo
| ColumnName |
DataType |
| Name |
string |
| CompanyName |
string |
| Longitude |
Decimal |
| Latitude |
Decimal |
| Description |
string |
| ImagePath |
string |
| Settings |
string |
| MenuType |
string |
| MenuData |
string |
| Master |
bool |
| Enabled |
bool |
OutputAdapters
| ColumnName |
DataType |
| ID |
int |
| AdapterName |
string |
| AssemblyName |
string |
| TypeName |
string |
| Connectionstring |
string |
OutputStreamDevicePhasors
| ColumnName |
DataType |
| OutputStreamDeviceID |
int |
| ID |
int |
| Label |
string |
| Type |
string |
| Phase |
string |
| ScalingValue |
int |
| LoadOrder |
int |
| CreatedOn |
DateTime |
| CreatedBy |
string |
| UpdatedOn |
DateTime |
| UpdatedBy |
string |
OutputStreamDeviceAnalogs
| ColumnName |
DataType |
| OutputStreamDeviceID |
int |
| ID |
int |
| Label |
string |
| Type |
int |
| ScalingValue |
int |
| LoadOrder |
int |
| CreatedOn |
DateTime |
| CreatedBy |
string |
| UpdatedOn |
DateTime |
| UpdatedBy |
string |
OutputStreamDeviceDigitals
| ColumnName |
DataType |
| OutputStreamDeviceID |
int |
| ID |
int |
| Label |
string |
| MaskValue |
int |
| LoadOrder |
int |
| CreatedOn |
DateTime |
| CreatedBy |
string |
| UpdatedOn |
DateTime |
| UpdatedBy |
string |
OutputStreamDevices
| ColumnName |
DataType |
| ParentID |
int |
| ID |
int |
| IDCode |
int |
| Acronym |
string |
| BpaAcronym |
string |
| Name |
string |
| PhasorDataFormat |
string |
| FrequencyDataFormat |
string |
| AnalogDataFormat |
string |
| CoordinateFormat |
string |
| LoadOrder |
int |
OutputStreamMeasurements
| ColumnName |
DataType |
| AdapterID |
int |
| Historian |
string |
| PointID |
int |
| SignalReference |
string |
Statistics
| ColumnName |
DataType |
| ID |
int |
| Source |
string |
| SignalIndex |
int |
| Name |
string |
| Description |
string |
| AssemblyName |
string |
| TypeName |
string |
| MethodName |
string |
| Arguments |
string |
| IsConnectedState |
bool |
| DataType |
string |
| DisplayFormat |
string |
| Enabled |
bool |
SubscriberMeasurementGroups
| ColumnName |
DataType |
| SubscriberID |
Guid |
| MeasurementGroupID |
int |
| Allowed |
bool |
| CreatedOn |
DateTime |
| CreatedBy |
string |
| UpdatedOn |
DateTime |
| UpdatedBy |
string |
SubscriberMeasurements
| ColumnName |
DataType |
| SubscriberID |
Guid |
| SignalID |
Guid |
| Allowed |
bool |
| CreatedOn |
DateTime |
| CreatedBy |
string |
| UpdatedOn |
DateTime |
| UpdatedBy |
string |
Subscribers
| ColumnName |
DataType |
| ID |
Guid |
| Acronym |
string |
| Name |
string |
| SharedSecret |
string |
| AuthKey |
string |
| ValidIPAddresses |
string |
| RemoteCertificateFile |
string |
| ValidPolicyErrors |
string |
| ValidChainFlags |
string |
| AccessControlFilter |
string |
| Enabled |
bool |
| CreatedOn |
DateTime |
| CreatedBy |
string |
| UpdatedOn |
DateTime |
| UpdatedBy |
string |